Working Reefer Container Buyer's Guide: Working vs. Non-Working, Capacity, Inspection, and Best Uses
A working reefer holds a set temperature and needs three-phase power, while a non-working reefer is insulated storage with no cooling. Choose a working unit for perishables, a climate-controlled container for temperature-sensitive dry goods, and a walk-in unit only for cold storage that must be kept inside a building. Inspect the refrigeration unit, not just the box.
Buying a reefer comes down to four decisions: working or non-working, reefer or an alternative, how much it holds, and whether the unit you are looking at actually works. Most mistakes happen at the last one, because a reefer can look fine and still fail to hold temperature.
This guide covers each decision in order. For the cost and timeline comparison with a built walk-in, see our reefer vs. walk-in cooler guide. For power, temperature limits, energy cost, and monitoring, see our reefer power and operating guide. This guide is not electrical or food-safety advice; consult a licensed electrician, a reefer technician, and your local health authority.
Working vs. Non-Working Reefer: Which One Do You Need?
A working reefer has an operating refrigeration system that cools or heats to a set point and needs power. A non-working reefer keeps the insulated box but not the machinery, so it stores goods at ambient-driven temperatures. Buy working for perishables and non-working only where insulation alone is enough.
|
Factor |
Working reefer |
Non-working reefer |
|---|---|---|
|
Refrigeration |
Operating system that cools and heats |
Non-operational unit, no active cooling |
|
Inslation |
Insulated box |
Insulated box, listed as highly insulated |
|
Power |
Three-phase power required; Container One lists 480 V |
None needed for cooling |
|
Temperature control |
Holds a set point |
Drifts toward outdoor temperature over time |
|
Repair risk |
Machinery can fail or need service |
No operating machinery, and no cooling unless repaired |
|
Price |
Higher |
Lower, per Container One's collection page |
|
Best uses |
Chilled and frozen storage, produce, floral, catering |
Insulated storage, workshops, and conversions |
|
Expert Insight: A Non-Working Reefer Does Not Become a Working One With a Plug Plugging in a non-working unit will not make it cool, because the refrigeration system is not operating. Adding cooling later is a separate project with its own equipment, and an air conditioner is built for comfortable indoor temperatures, not for holding food at refrigerated or frozen set points. If the goods need a set temperature, buy a working unit. |
Container One lists the 20 ft non-working reefer and the 20 ft working reefer, and offers 40 ft high cube versions of both. A non-working unit is a good fit for insulated storage without a constant power source, as noted in the 20 ft refrigerated collection.
Reefer, Climate-Controlled Container, or Walk-In Cooler?
Choose by the temperature the goods need. A reefer holds refrigerated and frozen set points for perishables. A climate-controlled container uses an air conditioner and heater to keep dry goods stable in a comfortable range. A walk-in cooler is built into a building and is suited for cold storage that must sit inside it.
|
Factor |
Working reefer |
Climate-controlled container |
|---|---|---|
|
Temperature capability |
Set points for chilled or frozen storage, depending on the unit |
Air conditioner and heater for a comfortable, stable range |
|
Insulation |
Factory-insulated reefer box |
2LB spray foam, 10.5 R-value, per Container One's listing |
|
Power |
Three-phase; Container One lists 480 V and 8 to 15 amps |
100 Amp service panel, 18,500 BTU A/C with heat, and a 50 Amp generator inlet, per the listing |
|
Floor |
Reefers typically have an air-channel T-floor |
Standard container floor |
|
Best for |
Perishable food, produce, flowers, beverages |
Electronics, documents, art, furniture, and other temperature-sensitive dry goods |
|
Watch-outs |
Power supply, loading rules, and inspection |
Not designed to hold food-safe cold temperatures |
Container One's climate-controlled collection covers insulated units for dry goods, and its listing for the 20 ft climate-controlled unit shows the included features. Ask what the specific unit controls before relying on it for anything beyond temperature.
A walk-in cooler wins when cold storage must be inside the building envelope, directly reachable from the kitchen or sales floor, or built to an irregular footprint. A reefer wins when you need capacity on a lot, on leased property, or on land with no building. The reefer vs. walk-in guide compares them in detail.
Reefer Capacity and Pallet Airflow
A reefer holds fewer pallets than a dry container of the same length because insulation reduces the interior space, and the load must leave room for airflow. Based on Container One's listed interiors, a 20 ft working reefer fits about 9 standard pallets, and a 40 ft high cube about 20 in one layer.
|
Unit |
Interior (L x W x H) |
Door opening |
Volume and floor |
Standard 48 x 40 in pallets |
Euro pallets |
|---|---|---|---|---|---|
|
20 ft working reefer |
17 ft 11 in x 7 ft 6 in x 7 ft 5 in |
7 ft 6 in x 7 ft 5 in |
1,003 cu ft; about 134 sq ft |
9 pinwheel, 8 straight |
10 pinwheel, 8 straight |
|
40 ft high cube working reefer |
38 ft x 7 ft 6 in x 8 ft 4 in |
7 ft 6 in x 8 ft 5 in |
2,366 cu ft; about 285 sq ft |
20 pinwheel, 18 straight |
23 pinwheel, 18 straight |
These are calculated single-layer floor positions, not field-tested counts. They assume a 4-inch gap at the door end, and the load must still stay below the unit's red load line. Confirm with a pallet trial on the exact unit. The method for counting pallets is explained in our pallet capacity guide.
Load Around the Airflow
A reefer is loaded around its airflow. Cold air is pushed through the floor channels, rises through the cargo, and returns over the top. Keep cargo below the red load line, stop at the end of the floor channels, cover vacant floor, and load product that is already at its target temperature.
- Red load line: never load above the line marked on the interior walls, because it protects the return airflow.
- Floor channels: never load past the end of the T-floor or block its channels.
- Vacant floor: cover any open floor area with dunnage or cardboard, since air takes the path of least resistance.
- Pre-cooled product: a reefer is built to hold temperature, not to chill warm cargo.
- Air supply: keep cargo clear of the air outlet and the bulkhead at the unit end.
- Doors: keep openings short, and do not run the unit with the doors open.
Shipping-line guidance from MSC and ONE describes the same rules, and the markings on your unit take priority.
|
Expert Insight: Capacity Is Not Access A reefer is designed to be block-loaded and left alone, not used as a walk-in room. The counts above assume pallets packed to cover the floor with no aisle. If staff will pull product several times a day, plan for fewer pallets, a covered floor where product is removed, and a longer wait for the unit to return to its set temperature after each opening. |
How to Inspect a Used Reefer Before You Buy
Inspect a used reefer in six steps: read the nameplate, review alarms and records, inspect the box, run a function test, run a pull-down test, and get terms in writing. A box that looks clean can still have a refrigeration unit that cannot hold temperature, so the machinery check matters most.
- Photograph the nameplate and controller: Ask for photos of the nameplate and the controller display for the exact unit, and confirm that the voltage and phase match your site.
- Review alarms, hours, and service records: Ask for the controller's alarm history, check run hours if they are displayed, and request any service records for the unit.
- Inspect the box: Check door seals, wall and floor panels, the T-floor channels, drains, and the interior for damage, corrosion, and odor.
- Run a function test: Have a technician run the controller's test sequence and confirm the fans, compressor, defrost, and alarms respond correctly.
- Run a pull-down test: Record ambient temperature, starting temperature, set point, and the time the empty unit takes to reach set point, then compare it with the technician's expectation.
- Get acceptance terms in writing: Confirm what happens if the unit fails the test or arrives different from the listing, and get the warranty terms for that specific unit in writing.
A pre-trip inspection, or PTI, is the industry term for this kind of check on an empty reefer. According to Harbor Reefer Service, it is an operational inspection and not an official container certification, so ask what testing was done on your specific unit.
What Container One's Inspection Covers
Container One's published five-point inspection checks the container shell: holes, seals, floors, doors, and door handles. It does not describe refrigeration testing. For a reefer, ask what function and pull-down testing was done on the specific unit, and arrange your own technician check where you can.
Read the full inspection process and note that Container One's FAQ page states that a buyer can refuse delivery if the container does not match the purchased grade. Ask for the warranty terms for your specific unit in writing, and photograph the unit on arrival before the driver leaves.
Sanitation and Food-Use Checks
A used reefer requires a sanitation review before it can hold food. It may have carried other cargo, so check for odor, residue, drain condition, and damage to cleanable surfaces. Your local health authority sets the rules for food storage, so confirm them before you buy.
- Odor and residue: a lingering smell or sticky floor can mean prior cargo, so clean and recheck.
- T-floor and drains: clear the channels and drains so water does not collect and spread contamination.
- Interior surfaces: reefer interiors are typically metal and cleanable, so look for corrosion, damage, and anything that cannot be cleaned.
- Pests: inspect door seals and gaps for pest entry before loading product.
- Records: keep your cleaning steps and temperature logs, as inspectors and customers may request them.
FDA and USDA guidance sets refrigerator temperatures at 40 degrees Fahrenheit or below and freezer temperatures at 0 degrees Fahrenheit or below, as stated by the FDA and USDA FSIS. Produce, flowers, beverages, and medicines have their own ranges, so confirm yours with a qualified reviewer.
Best-Use Matrix: Which Container Fits Which Job
Match the container to the goods. Perishable food and produce need a working reefer, temperature-sensitive dry goods suit a climate-controlled container, and goods that only need insulation can go in a non-working reefer or a standard container. Medicines and vaccines need a qualified review before any choice.
|
Use |
What matters |
Best fit |
Watch-outs |
|---|---|---|---|
|
Restaurant chilled or frozen overflow |
Set point and easy access |
Working reefer |
Door openings, power at the placement point, health rules |
|
Restaurant dry goods and paper |
Dry, secure space |
Dry or insulated container |
Pest control and shelving |
|
Produce growers |
Fast cooling and holding |
Working reefer |
Reefers hold temperature, so pre-cool; humidity needs vary by crop |
|
Florists and caterers |
Steady cold holding |
Working reefer |
Ranges differ by product; plan a generator for events |
|
Farm meat, dairy, and eggs |
Regulated food storage |
Working reefer |
Check state and federal rules first |
|
Documents, art, electronics, furniture |
Stable room-range temperature |
Climate-controlled container |
Confirm what the unit controls |
|
Insulated storage without power |
Insulation only |
Non-working reefer |
No cooling, and temperature drifts with weather |
|
Medicines and vaccines |
Documented, validated temperature |
Qualified review first |
Do not decide from a general guide |
What a Reefer Costs to Run
Operating cost depends on how hard the unit works. Published research cites mean draws of about 4 kW for a 20-ft reefer and 7 kW for a 40-ft unit, or roughly 96 and 168 kWh per day, with wide variation. Weather, setpoint, door openings, and unit condition affect the number.
Use those figures as a starting point only, and measure your own with a submeter. Our reefer power and operating guide [LINK ONCE LIVE] gives low, base, and high scenarios, the electrical connection checklist, and monitoring and backup power guidance. The research is from Energy Policy. For delivery and placement, see the delivery guide and the permit and zoning guide.
Choose a Reefer and Confirm the Details
Container One sells working and non-working refrigerated containers in 20-ft and 40-ft high-cube models, delivered nationwide from 300+ inventory locations. Enter your ZIP code to view current availability and delivery pricing, and ask for the nameplate details, test results, and warranty terms for the specific unit.
Browse the 20 ft refrigerated containers and 40 ft refrigerated containers, or open the 20 ft working reefer and 40 ft high cube working reefer pages for listed specifications. Review the financing options, or call 330-286-0526.
Frequently Asked Questions About Buying a Reefer Container
1. What is the difference between a working and a non-working reefer container?
A working reefer has an active refrigeration system, needs power, and holds a set temperature. A non-working reefer retains its insulation but has no operating refrigeration, so it requires no power for cooling and will not maintain a set temperature on its own.
2. Can I use a non-working reefer as cold storage?
No. Without an operating refrigeration system, it only slows temperature change, so contents drift toward the outdoor temperature. It suits insulated storage and conversions, not perishable food.
3. How many pallets fit in a reefer container?
Calculated from Container One's listed interiors, a 20 ft working reefer holds about 9 standard 40 by 48 inch pallets or 10 Euro pallets in one layer, and a 40 ft high cube about 20 or 23. Straight loading holds fewer, and airflow rules apply.
4. Why can't I load a reefer to the ceiling?
A reefer circulates cold air through the floor channels, up through the cargo, and back over the top. Loading above the red load line, or past the end of the floor blocks, blocks airflow and creates warm spots.
5. Is a reefer better than a climate-controlled container?
It depends on the goods. A reefer is built to hold refrigerated or frozen set points for perishables. A climate-controlled container uses an air conditioner and heater to keep dry goods in a stable, comfortable range.
6. Is a reefer better than a walk-in cooler?
A reefer is delivered, sits outdoors, and moves with you. A walk-in is built into a building and stays. The right choice depends on whether the cold storage must be inside the building or can sit on the lot.
7. What should I check when buying a used reefer?
Check the nameplate and voltage, controller alarms and hours, service records, door seals, panels, floor channels, and drains, and ask for a function test and a pull-down test result for that specific unit.
8. Can I store food in a used reefer container?
Many operators do, but a used unit needs cleaning and inspection first, and your local health authority sets the rules. Confirm requirements with them and with a food-safety professional before storing food.
9. What power does a working reefer need?
Container One lists its working 20 ft and 40 ft high-cube reefers at 480 volts, three-phase, drawing 8 to 12 amps and 8 to 15 amps, respectively. Confirm the nameplate and site supply with a licensed electrician before ordering.
10. How much does it cost to run a reefer?
Published research cites mean draws of about 4 kW for a 20-ft unit and 7 kW for a 40-ft unit, corresponding to roughly 96 and 168 kWh per day, with wide variation. A submeter on your own unit gives you your real cost.
|
Ready to Choose Your Reefer? Get Your Delivered Price. 300+ depot locations. Delivery is included in the price shown for your ZIP code. Financing from 12 to 60 months. A+ BBB rating. Get your quote at containerone.net or call 330-286-0526. |